Technical data
Nominal input voltage 24VInput voltage range 21 –32V (44V max.)Continuous power @ 25°C 500VAPower 30 min. @ 25°C 600VAPower 5 min. @ 25°C 675VAPower 5 sec. @ 25°C 1200VAMax asymmetrical load 300VAShort circuit current 2s (output) 5.7AOutput voltage True sine 230Vac 0 / -10%Frequency 50Hz ± 0.05% (Crystal control)Distortion THD (on resistive load) < 5% (@ Pnom)Consumption in « Stand-by » mode 0.4WConsumption « ON » @ no load 8.5WMaximum efficiency 94%Max continuous Cos ? 0.1 – 1 up to 500VALoad detection Adjustable: 1 ? 20WOverheating protection (+/-5°C) Shut down @ 75 °C – Auto-restart @ 70°COverload protection Automatic disconnection with 2 time restart attemptShort circuit protection Automatic disconnection with 2 time restart attemptReverse polarity protection Protected by internal fuseBack feed protection Not protectedBattery deep discharge protection Shut off @ 0.87 x Unom – Automatic restart @ UnomOver voltage shut down Shut off @ >1.33 x Unom - Automatic restart @ < UmaxAcoustic warning Before low battery or overheating disconnectionCable length(Battery / AC out) 1.5m / 1mNoise > 45 dB (Ventilation)Operating temperature -20°C up to +50°CApprox. output power derating -1.5%/°C since +25°CIP protection index IP 30 conforms to DIN 40050Forced ventilation From 45°C ± 5°CRequired battery capacity > 5 x Pnom/Unom (recommended value in Ah)Weight & dimensions 4.5 kg – 142mm x 240mm x 84mmWarranty 2 yearsE norm ECE-R 10 (E24) certification for 12 and 24V modelsEC conformity compliance EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2,Dir. 89/336/EEC, LVD 73/23/EEC